Discover why a servo motor won’t operate if the STO (Safe Torque Off) input on its drive is left open. This crucial safety feature prevents unwanted movement by electronically disabling torque, ensuring personnel safety during maintenance and operation.
Practical notes for CNC router, automation and industrial motion systems.
Understanding the STO (Safe Torque Off) Function in Servo Drives
In industrial automation, particularly within advanced motion control systems like those found in CNC router machines, safety is paramount. The STO (Safe Torque Off) function is a cornerstone of modern servo drive technology, designed to prevent unexpected or hazardous machine movements. Its primary role is to electronically interrupt the power supply to the motor windings, thereby eliminating the possibility of torque generation. Even if the servo drive receives electrical power, the STO function ensures that no current reaches the motor, rendering it incapable of rotation or movement. This is vital for protecting personnel during maintenance, setup, or troubleshooting operations.
When an STO input is described as “open” or “left open,” it typically means that the input is not actively energized by a safety control circuit, such as a safety relay or safety PLC. Most servo drives are designed with a “fail-safe” principle, meaning they default to a safe, torque-off state. To enable motor operation, a specific voltage (commonly 24V DC) must be applied to the STO inputs. Without this active signal, the drive will not permit the motor to produce torque. This inherent safety design ensures that in the event of a fault, such as a wiring issue or power interruption, the system automatically defaults to its safest state.
How STO Works: Principles and Technical Specifications
The Safe Torque Off (STO) function is critical for safely stopping electric motors and preventing unintended restarts. Its operational principle involves directly disabling the power electronics switches (like IGBTs) within the servo drive that supply power to the motor. This action physically prevents the motor from generating torque, even if the drive’s control circuitry remains powered and operational for diagnostic purposes.
STO functionality is typically implemented with a dual-channel (redundant) design. This requires simultaneous activation of two independent inputs (STO1 and STO2) to disable the safety feature. This redundancy ensures that the safety function remains effective even if a single component fails, meeting stringent safety standards such as Safety Integrity Level (SIL) or Performance Level (PL). For instance, achieving PLd or PLe according to ISO 13849-1, or SIL2/SIL3 according to IEC 61508/IEC 62061, often necessitates dual-channel STO configurations. These inputs are controlled by an external safety device, such as a safety relay, safety PLC, or an emergency stop button. Upon detecting a safety violation, this external device de-energizes the STO inputs, preventing motor torque.
Servo drives continuously monitor the status of their STO inputs. A drop in voltage or complete loss of the required input voltage (typically 24V DC) is interpreted by the drive as a safety fault, triggering the STO function and disabling motor power. A corresponding error code or status indicator usually signals this event. To resume operation, the safety fault must be rectified, the STO inputs must be re-energized by the safety circuit, and the drive may require a reset. Some drives may also require periodic testing of the STO function to maintain compliance with safety standards.
The response time of the STO function is a critical technical parameter. Safety standards mandate that the STO function must disable motor torque within a specified, very short period, often measured in milliseconds. This rapid response is essential for mitigating hazards effectively. It’s important to note that STO typically allows the motor to coast freely; it does not engage an electric brake unless a separate braking function is activated. This characteristic is sometimes preferred in applications, such as vertical axes where a mechanical brake might be expected to engage.
| Parameter | Value/Description |
|---|---|
| STO Definition | Safe Torque Off |
| Purpose | Prevent unintended motor movement, ensuring personnel and machine safety. |
| Operating Principle | Disables power electronics switches to prevent motor torque generation. |
| Safety Level Compliance | Commonly meets ISO 13849-1 (PLd/PLe) or IEC 62061 (SIL2/SIL3) requirements. |
| Input Type | Typically dual-channel (redundant) digital inputs (STO1, STO2). |
| Typical Activation Voltage | 24V DC (for active state); 0V (for safe/torque-off state). |
| Response Time | Typically within milliseconds, depending on the manufacturer and safety level. |
| Relevant Standards | IEC 61800-5-2 (Adjustable speed electrical power drive systems – Safety requirements), ISO 13849-1 (Safety of machinery – General principles for design), IEC 62061 (Functional safety of safety-related electrical, electronic and programmable electronic systems). |

Key Considerations for Industrial Applications
- Correct Wiring and Connections: The wiring of STO inputs must adhere strictly to safety standards. For dual-channel inputs, using separate, shielded cables is highly recommended to prevent electrical noise (EMI/RFI) interference. Improper wiring can lead to malfunctioning STO functionality or spurious STO triggers, causing production downtime. Ensure all connection terminals are secure and correctly terminated.
- STO Input Activation and Reset Procedures: To enable motor operation, both STO inputs must be continuously energized (typically 24V DC) by the safety circuit (safety relay or PLC). Any interruption to this power will activate STO and stop the motor. After an STO event, the safety fault must be cleared, the safety circuit must re-energize the STO inputs, and the drive may need to be reset. The specific reset procedure can vary by drive model.
- Periodic Testing and Verification: Regular testing is mandatory to ensure the continued reliability of safety functions like STO, as required by standards such as ISO 13849-1. These tests involve intentionally disabling the STO inputs and verifying that the motor torque is indeed prevented. Test results must be meticulously recorded and documented to maintain safety integrity and regulatory compliance.
- Integration with Emergency Stops and Other Safety Functions: STO is typically part of a broader machine safety architecture. Emergency stop buttons, light curtains, safety door interlocks, and other safety devices can trigger the STO function, either directly or via safety relays/PLCs. Ensure this integration is correctly implemented and that the entire safety chain meets the required Performance Level or Safety Integrity Level. The design and validation of the safety circuit should be performed by qualified personnel.
- Documentation and Training: Comprehensive documentation detailing the STO implementation, safety circuit design, and operating procedures is essential. All personnel involved in operating or maintaining the machinery must receive adequate training on the STO function, its implications, and the correct procedures for normal operation, fault handling, and emergency situations.
Proper implementation and understanding of the STO function are critical for safe and efficient operation of industrial machinery. If you require assistance with selecting or integrating servo drives with STO capabilities for your CNC router machine or other industrial applications, our experts are ready to help. Request a quote on WhatsApp today!