Güç Kaynakları Eğitimleri EN

The Importance of Quality Power Supplies in Industrial Automation

17 min read Mermak CNC Technical Content
The Importance of Quality Power Supplies in Industrial Automation
Contents
  1. The Importance of Quality Power Supplies in Industrial Automation: Introduction and Technical Analysis
  2. The Importance of Quality Power Supplies in Industrial Automation: Operating Principle and Technical Data
  3. The Importance of Quality Power Supplies in Industrial Automation: Field Considerations
  4. The Importance of Quality Power Supplies in Industrial Automation: Common Problems and Solutions
  5. The Importance of Quality Power Supplies in Industrial Automation: Conclusion and Expert Advice
  6. FAQ

The Importance of Quality Power Supplies in Industrial Automation: Introduction and Technical Analysis

 

Industrial automation forms the backbone of modern manufacturing and process facilities. Every component used to ensure the efficiency, reliability, and sustainability of production lines has a critical impact on the system’s overall performance. Among these components, power supplies, often overlooked but vital as the system’s lifeline, play a role as critical as PLCs, sensors, or motors. A low-quality power supply can directly threaten the stability, reliability, and thus the production continuity of the entire automation system. As experts, we emphasize that it is not enough for power supplies used in industrial automation to merely “work”; they must be high-quality products that meet specific industrial standards and expectations.

Industrial automation systems are often exposed to harsh operating conditions: high temperatures, humidity, dust, vibration, and electrical noise. In such environments, standard commercial power supplies can fail quickly or experience performance degradation. In contrast, industrial-grade quality power supplies are specifically designed and manufactured to withstand these challenges. This is not limited to the physical durability of the hardware; it also includes technical parameters such as electrical performance, stability, protection features, and longevity. Every electronic component in an automation system, from sensors to PLCs, HMI panels to actuators, requires a precise and stable DC power supply. Any fluctuation, noise, or interruption in this supply can lead to system malfunctions, data loss, control deviations, and, in the worst-case scenario, production downtime. Therefore, the technical analysis of industrial power supplies requires much more than just checking nominal output voltage and current values; parameters such as efficiency, ripple, noise, overload and short-circuit protection, EMC compliance, and MTBF (Mean Time Between Failures) are critically important for the long-term performance and reliability of the system.

In this guide, we will comprehensively cover why the selection of a quality power supply is indispensable in industrial automation applications, its technical details, operating principles, field considerations, and solutions for common problems. Our goal is to help engineers, technicians, and system integrators make more informed decisions when selecting power supplies for automation projects, thereby increasing the overall reliability and efficiency of their systems. It should be remembered that the weakest link in an automation system can often be its least-noticed component, and this is often the power supply. The right choice affects not only the initial investment cost but also operational costs, maintenance times, and most importantly, production losses.

The Importance of Quality Power Supplies in Industrial Automation: Operating Principle and Technical Data

In industrial automation systems, the primary purpose of power supplies is to convert alternating current (AC) from the mains into stable and regulated direct current (DC) required by automation components. This conversion process is largely achieved with Switched-Mode Power Supply (SMPS) technology. SMPS units offer much higher efficiency, smaller size, and lighter weight compared to traditional linear power supplies, making them ideal for industrial applications.

The operating principle of an SMPS can be summarized as follows: First, the mains voltage (e.g., 230V AC) is rectified and converted into a high-voltage DC. Then, this DC voltage is converted into a square wave form via a high-frequency switching circuit (typically using MOSFETs or IGBTs). This high-frequency AC signal is passed through a small transformer to reduce it to the desired output voltage level and provide galvanic isolation. After the transformer, this high-frequency AC is rectified again, and a smooth DC output voltage is obtained using a filter circuit (capacitors and inductors). A feedback loop continuously monitors the output voltage and adjusts the switching circuit to keep the voltage at its nominal value; this is known as voltage regulation.

Key technical data and features to look for in a quality industrial power supply include:

  • Input Voltage Range: Industrial environments are often subject to voltage fluctuations. A wide input voltage range (e.g., 85-264 VAC or 120-370 VDC) ensures stable operation of the power supply under varying mains conditions.
  • Output Voltage and Current: Selecting the correct voltage (typically 24V DC) and sufficient current capacity (with 20-30% extra capacity) to meet the total power requirements of automation components is critical.
  • Efficiency: High efficiency (typically 90% and above) reduces energy losses, lowers heat generation, and decreases operating costs. Less heat extends the lifespan of components.
  • Ripple & Noise: These are undesirable AC components in the output voltage. Low ripple and noise (typically specified in mVpp) are vital for the accurate operation of sensitive electronic components (sensors, PLC analog inputs). Quality power supplies keep this value to a minimum (e.g., less than 50mVpp).
  • Voltage Regulation: Indicates how stable the output voltage remains during load changes or input voltage fluctuations. It is expressed as a percentage (e.g., ±1% or better).
  • Overload Protection: The power supply’s ability to protect itself when the output current exceeds its nominal value. This is typically achieved through constant current, hiccup mode, or shutdown methods.
  • Short Circuit Protection: Protects the power supply and connected devices when a short circuit occurs at the output. Automatic recovery features are preferred.
  • Over Voltage Protection (OVP): Prevents the output voltage from exceeding a specified level, protecting connected equipment.
  • Over Temperature Protection (OTP): Shuts down the power supply to prevent damage when its internal temperature reaches a critical level.
  • EMC/EMI Compliance: Compliance with electromagnetic compatibility (EMC) and electromagnetic interference (EMI) standards (e.g., EN 61000 series) ensures that the power supply does not interfere with other devices and is immune to external interference. The CE mark is an indicator of this.
  • MTBF (Mean Time Between Failures): A statistical measurement indicating how long a device can operate without failure. A high MTBF (e.g., over 500,000 hours) for industrial power supplies signifies long life and reliability.
  • Operating Temperature Range: A wide operating temperature range (e.g., -25°C to +70°C) guarantees reliable operation in harsh industrial environments. Derating curves for power reduction at high temperatures should be considered.
  • Redundancy and Parallel Operation Capability: Some models offer special features for N+1 redundancy or parallel operation, which increases system reliability.
  • Certifications: Compliance with industrial standards and safety regulations such as UL, cUL, CE, CCC, ATEX (for explosive atmospheres) confirms the product’s quality and reliability.

These technical data points indicate not only the nominal values of a power supply but also how reliably and stably it will operate under demanding industrial conditions. Choosing a high-quality power supply ultimately reduces the total cost of ownership, minimizes maintenance needs, and maximizes production continuity.

ParameterValue/Description
Input Voltage Range85-264 VAC (Universal), 120-370 VDC
Output Voltage24 VDC (Adjustable ±10%)
Output Current10A (240W)
Efficiency> 90% (At full load)
Ripple & Noise< 50 mVpp (At 20 MHz bandwidth)
Voltage Regulation±0.5% (Including load and line regulation)
Protection FeaturesOverload, Short Circuit, Over Voltage, Over Temperature
MTBF (MIL-HDBK-217F)> 500,000 Hours (At 25°C)
Operating Temperature Range-25°C to +70°C (With derating)
EMC ComplianceEN 61000-6-2 (Industrial Environment Immunity), EN 61000-6-4 (Industrial Environment Emission)

The Importance of Quality Power Supplies in Industrial Automation: Field Considerations

  • Proper Sizing and Redundant Capacity: When selecting a power supply, the total current requirement of all connected devices (PLC, sensors, actuators, HMI, etc.) must be carefully calculated. It is strongly recommended to leave at least 20-30% redundant capacity, not only to meet the current load but also for future expansions and potential sudden current draws. This prevents the power supply from continuously operating at its maximum capacity, extending its lifespan and reducing the risk of overheating. Additionally, the instantaneous peak current capacity for inductive loads (contactors, solenoid valves) that draw high current at startup should be considered.
  • Environmental Adaptation and Mounting: Industrial environments often present challenging factors such as high temperatures, humidity, dust, and vibration. Ensure that the chosen power supply is resistant to these conditions. Features such as operating temperature range, IP protection class (against dust and water), and vibration resistance (IEC 60068-2-6 standard) should be checked. During mounting, ensuring sufficient airflow around the power supply is critical for heat dissipation. For DIN rail mounts, adequate spacing between other components should be maintained, and forced ventilation (fan) or air conditioning should be considered in enclosed panels. Power supply performance curves (derating curves) indicate that nominal current capacity may decrease at high temperatures; this should be taken into account during capacity planning.
  • EMC/EMI Compliance and Grounding: Industrial automation systems can be exposed to electrical noise (EMI) or emit this noise themselves due to motor drives, contactors, and other switching devices. Quality power supplies have internal EMI filters to suppress such noise and prevent it from affecting other system components, and they are tested in accordance with international EMC standards (e.g., EN 61000 series). However, the power supply itself is not enough; system-level measures such as proper grounding practices, the use of shielded cables, and routing power cables separately from signal cables are also vital. Inadequate grounding or incorrect wiring can adversely affect the power supply’s EMC performance, leading to erroneous readings in sensitive sensors or PLC inputs.
  • Redundancy and Reliability Strategies: In critical automation applications, redundancy strategies should be implemented to prevent power supply failures from causing production downtime. An N+1 redundancy configuration is based on the principle that multiple power supplies are connected in parallel to share the total load, and if one power supply fails, the others take over the load. For such applications, power supplies may need to have current sharing capability or an external redundancy module may be required. This significantly increases the overall reliability of the system and minimizes losses due to unexpected failures.
  • Cabling and Connection Quality: The cross-section of cables running from the power supply’s output to the loads should be appropriate for the current drawn and chosen to minimize voltage drop. Long and thin cables can cause voltage drop, leading to devices operating at low voltage and performance loss. All connections must be solid, corrosion-free, and tightened to the correct torque to reduce electrical resistance and prevent heat generation. Periodic checks should be performed to ensure that connections, especially to terminal blocks, do not loosen over time.

The Importance of Quality Power Supplies in Industrial Automation: Common Problems and Solutions

Common problems with power supplies in industrial automation systems usually stem from incorrect selection, installation, or environmental factors. Early detection and correct solutions for these problems ensure continuous system operation.

  • Output Voltage Ripple or Drop:
    • Scenario: Random errors in PLCs or sensors, unstable operation in actuators are observed. When measured with a multimeter, the output voltage is below the nominal value or fluctuating.
    • Possible Causes: Overloading of the power supply, voltage drop due to long or insufficient cross-section cables, wear or failure of internal components of the power supply (especially electrolytic capacitors), large fluctuations in mains voltage.
    • Solution:
      1. Recalculate the total current of all loads and check the power supply’s capacity. If necessary, replace with a higher capacity power supply or distribute the load.
      2. Check the cross-section of the output cables and shorten the distance. Consider separate supply lines for devices drawing large currents.
      3. Check the operating ambient temperature of the power supply; excessive temperatures shorten component life.
      4. Monitor the mains voltage; if there are large fluctuations, integrate a voltage regulator or UPS on the input side.
      5. Test if the problem persists by replacing the power supply.
  • Overheating and Premature Failure:
    • Scenario: The power supply is too hot to touch, frequently shuts down, or its lifespan is shorter than expected.
    • Possible Causes: Insufficient cooling (lack of ventilation space), overloading, high ambient temperature, internal component failure (especially fan failure in fan-equipped models).
    • Solution:
      1. Ensure the minimum air gaps specified by the manufacturer around the power supply.
      2. Use ventilation or air conditioning systems to reduce the temperature inside the panel.
      3. Ensure the power supply is not operating above its nominal capacity; replace with a larger model if necessary.
      4. Perform regular maintenance and cleaning to prevent dust accumulation.
      5. Check if over-temperature protection is being activated.
  • Sudden Interruptions and Shutdowns:
    • Scenario: The system instantly shuts down and restarts, or the power supply resets itself at intervals.
    • Possible Causes: Overload protection activation (especially instantaneous current draws), short circuit or grounding fault, sudden voltage dips or surges from the mains, loose connections.
    • Solution:
      1. Check all loads in the system, especially devices that draw high current at startup, such as motors or contactors. Select a power supply that can handle instantaneous current draws.
      2. Check all output cables and connected devices for short circuits or grounding faults.
      3. Monitor the mains voltage with a power analyzer to determine if there are sudden dips or surges. Use a mains filter or UPS if necessary.
      4. Ensure all connections are tight and secure.
  • Electromagnetic Interference (EMI) Issues:
    • Scenario: Malfunctions, data corruption, or instability occur in nearby electronic devices (e.g., sensors, communication modules).
    • Possible Causes: Non-compliance of the power supply or other devices with EMC standards, incorrect grounding, lack of shielded cables, power and signal cables routed too close together.
    • Solution:
      1. Check the EMC certifications of the power supply and other critical components.
      2. Review the grounding scheme of the entire system and provide appropriate grounding points.
      3. Use shielded cables for sensitive signal cables and ground their shields correctly.
      4. Route power cables as far as possible from data and signal cables.
      5. If necessary, add an additional EMI filter to the input side.

The Importance of Quality Power Supplies in Industrial Automation: Conclusion and Expert Advice

In the complex and dynamic world of industrial automation, the overall performance and reliability of a system depend on the quality of its most fundamental components. The power supply, often overlooked among these components, is a vital element that acts as the “heart” of the entire system. Our many years of field experience have repeatedly shown that a low-quality or incorrectly selected power supply, while initially appearing as a small cost saving, can lead to much larger operational costs, production downtime, maintenance expenses, and even safety risks in the long run.

Investing in a quality industrial power supply is not just an expense; it is a strategic investment in the future performance, reliability, and sustainability of your system. Technical features such as high efficiency, low ripple and noise, wide operating temperature range, comprehensive protection features, and compliance with international standards are not just figures on paper; they are guarantors of operational continuity in the field. The MTBF value of a power supply does not just offer a theoretical lifespan; it also indicates how rarely unexpected failures will occur beyond planned maintenance. This directly translates to uninterrupted operation of the production line.

As expert advice, I would like to emphasize that you should give the selection of power supplies the importance it deserves in your automation projects. The share of power supplies in a project budget is usually low, but when they fail, the domino effect can cripple the entire system. Therefore, do not limit yourself to just looking at nominal power values. Carefully examine the manufacturer’s reputation, product tests and certifications, technical support quality, and warranty conditions. Choosing a model with an appropriate IP protection class for environmental conditions, sufficient redundant capacity, and allowing for future expansions will provide significant benefits in the long run. Furthermore, never underestimate the impact of factors such as correct cabling, proper grounding, and adequate ventilation on the overall system performance during installation. Remember, the strength of an automation system is only as strong as its weakest link; and this link, if not chosen correctly, can often be the power supply. Do not compromise on quality power supplies for safe, efficient, and uninterrupted production.

FAQ

Why are quality power supplies crucial for industrial automation systems?

A quality industrial power supply ensures stable and reliable power delivery to all automation components, preventing malfunctions, data loss, and production downtime. It is designed to withstand harsh industrial environments, offering high efficiency, robust protection features, and a long operational lifespan.

What technical specifications should I look for in an industrial power supply?

Key technical specifications include a wide input voltage range, stable output voltage and sufficient current capacity, high efficiency (typically >90%), low ripple and noise (

What are the critical field considerations for installing industrial power supplies?

Ensure proper sizing with at least 20-30% redundant capacity for future expansion and peak loads. Verify compliance with environmental conditions (temperature, humidity, IP rating). Implement correct grounding and use shielded cables to prevent EMI. Consider redundancy strategies (N+1) for critical applications and ensure high-quality, properly sized cabling with secure connections.

What are common problems with industrial power supplies and how can they be resolved?

Common issues include output voltage fluctuations, overheating, sudden shutdowns, and electromagnetic interference. Solutions involve recalculating load requirements, improving ventilation, checking for short circuits or grounding faults, monitoring mains voltage, and ensuring proper EMC practices like shielded cabling and correct grounding.

How does an industrial SMPS (Switched-Mode Power Supply) work?

An SMPS (Switched-Mode Power Supply) converts AC mains voltage to a stable DC voltage required by automation components. It rectifies the AC, switches it at high frequency, transforms it to the desired level, then rectifies and filters it again to produce a smooth DC output, with a feedback loop for voltage regulation.

⚙ Tools